EN ISO 11612 is the international standard for clothing that protects against heat and flame. It is the standard most buyers name for flame-resistant (FR) coveralls, jackets, shirts and trousers worn in oil and gas, petrochemical plants, foundries, utilities and other industries where a worker can be exposed to fire, radiant heat or molten metal.
This guide explains the code letters you see on an EN ISO 11612 label, how they relate to real hazards, how the standard differs from EN ISO 11611 for welding, and what to specify when you order FR clothing.
How the standard works
EN ISO 11612:2015 tests the garment material, seams and design against several types of heat. Every certified garment must pass the flame-spread test (code A). It must also pass at least one of the heat tests (codes B to F). The label lists each code the garment achieved, with a performance level where the test has levels; the higher the number, the better the protection.
| Code | Hazard | Levels | What it means |
|---|---|---|---|
| A1 / A2 | Limited flame spread | Pass | Fabric does not keep burning or melt after a small flame touches its surface (A1) or edge (A2) |
| B | Convective heat | B1–B3 | Protection against hot air and flames |
| C | Radiant heat | C1–C4 | Protection near furnaces and other hot surfaces that radiate heat |
| D | Molten aluminium splash | D1–D3 | For aluminium casting and foundries |
| E | Molten iron splash | E1–E3 | For iron and steel foundries |
| F | Contact heat | F1–F3 | Protection when touching hot objects |
A typical FR coverall for oil and gas or general industry might carry A1 B1 C1. A foundry jacket would add D or E levels. The right combination depends on the risk assessment of the site where the garment will be worn, so ask your customer which codes they need.
Flame-resistant fabrics
Protection comes from the fabric. There are two main types:
- Inherently flame-resistant fibres, such as aramids and modacrylic blends, whose protection is part of the fibre and does not wash out.
- FR-treated fabrics, usually cotton or cotton-rich blends treated with a durable flame-retardant finish, which are comfortable and economical but must be washed as the label instructs.
The rest of the garment must match: FR sewing thread, covered or non-melting zips and press studs, and flame-resistant reflective tape if the garment also needs to be visible. A garment made from FR fabric but sewn with ordinary polyester thread will not pass.
EN ISO 11612 vs EN ISO 11611
The two standards are often confused:
- EN ISO 11612 covers heat and flame in general.
- EN ISO 11611 covers welding and allied processes: small spatter of molten metal, short contact with flame and radiant heat from the arc. Read our guide to EN ISO 11611 Class 1 vs Class 2.
Many FR garments are certified to both, which suits sites where workers weld occasionally. If there is also a risk of electric arc, see our guide to FR vs arc-rated clothing.
What to put in your specification
- The standard and the codes required, for example “EN ISO 11612 A1 B1 C1”, plus EN ISO 11611 or IEC 61482-2 if needed.
- Fabric type (inherent or treated), composition and weight in g/m².
- Colour, and whether hi-vis reflective tape is needed (it must be flame-resistant).
- Closures: covered zip or press studs; pockets with flaps.
- Logo method: embroidery with FR thread, or a heat-applied FR transfer.
- Size range and wash instructions.
- Documents: ask for the certificates and fabric test reports that apply to the exact model.
FR clothing from Gratex Industries
We make FR coveralls, FR jackets and FR pants and shirts in Sialkot from 25 pieces per style, including the FR coverall with reflective tape and the FR winter jacket. Tell us the codes you need and we will match the fabric and construction. See our certificates page for documents, or learn more about us as a workwear manufacturer.