All arc-rated clothing is flame-resistant, but not all flame-resistant clothing is arc-rated. Flame-resistant (FR) clothing is tested against fire and heat; arc-rated clothing is additionally tested against the intense energy of an electric arc flash and given a rating in cal/cm². If your customers work on or near live electrical equipment, they need arc-rated garments with a rating at least equal to the hazard on their site.

This guide explains the difference, what ATPV and EBT mean, how NFPA 70E PPE categories work, and what to specify when you order.

What an arc flash does

An arc flash is an electrical explosion: current jumps through the air between conductors, releasing extreme heat in a fraction of a second. Ordinary clothing can ignite and keep burning on the body. Arc-rated clothing is made from FR fabric that does not ignite and keep burning, and it limits the heat that reaches the skin.

FR vs arc-rated: the standards

FR clothingArc-rated clothing
Protects againstFlame, convective and radiant heat, molten metalAll of that, plus the thermal energy of an electric arc
Main standardsEN ISO 11612; NFPA 2112 (US flash fire)IEC 61482-2; NFPA 70E with ASTM F1506 (US)
Result shown asCode letters and levels (e.g. A1 B1 C1)Arc rating in cal/cm² (ATPV or EBT), or box-test class 1 or 2

ATPV and EBT

Arc-rated fabrics are tested in an open-arc test (IEC 61482-1-1 or ASTM F1959). The result is a single number in calories per square centimetre:

The garment’s arc rating is the lower of the two. A shirt rated 8 cal/cm² protects against an arc flash with incident energy up to 8 cal/cm².

Europe also uses a box test (IEC 61482-1-2), which gives Class 1 (tested at 4 kA) or Class 2 (tested at 7 kA). Many garments for the European market state both the open-arc rating and the box-test class.

NFPA 70E PPE categories

In the US, and on many international sites that follow US practice, NFPA 70E groups electrical tasks into PPE categories, each with a minimum arc rating:

PPE categoryMinimum arc ratingTypical clothing
CAT 14 cal/cm²Arc-rated shirt and trousers or coverall
CAT 28 cal/cm²Arc-rated shirt and trousers or coverall
CAT 325 cal/cm²Arc flash suit or layered arc-rated clothing
CAT 440 cal/cm²Arc flash suit

A garment rated 8 or 12 cal/cm² therefore meets CAT 2. Higher categories normally need layered systems or flash suits rather than a single shirt.

What to put in your specification

  1. The hazard: flame only, or flame and electric arc.
  2. For arc protection: the minimum arc rating (cal/cm²) or PPE category, and the box-test class if your market uses it.
  3. Any other standards needed, such as EN ISO 11612 or hi-vis EN ISO 20471.
  4. Fabric composition and weight; arc ratings depend on both.
  5. Closures, thread, labels and reflective tape that are themselves flame-resistant.
  6. Documents: ask for the arc test report and certificates for the exact model and fabric.

FR and arc-rated clothing from Gratex Industries

Our FR pants and shirts include styles listed at 8 cal/cm² and 12 cal/cm² for CAT 2 work, and the FR pant and shirt with reflective tape for sites that also need visibility. See our certificates page for the documents available, our guide to EN ISO 11612, or learn more about us as a workwear manufacturer.